On Mon, Jun 21, 2010 at 03:21:48PM -0400, Don Stanley wrote: > Hi Chris; > After I corrected my thread order the symptom remained the same. > > Additional information observed is; the first home after EMC has been > started the value loaded at the home/limit release point is approximately > the position the axis was at EMC start, as loaded from the > PARAMETER_FILE =. This is far enough to spike the "axis.n.f-error" off > the scale instantly and produce the Joint Following Error. > > I am running EMC 2.3.? off the last Live Disk install. > Maybe I could park the system at the limit switches before system shutdown. > Here is hoping there is better solution.
Hi Don, I wrote the following in this thread earlier but you don't say whether you did it or not. Did you? On Wed, Jun 16, 2010 at 01:43:46PM -0500, Chris Radek wrote: > > I assume you're homing to index. If so this sounds like the "homing > thump" problem. You should update to 2.4.1 and then hook up your > pid.N.index-enable pins to the corresponding index-enable nets. ------------------------------------------------------------------------------ ThinkGeek and WIRED's GeekDad team up for the Ultimate GeekDad Father's Day Giveaway. ONE MASSIVE PRIZE to the lucky parental unit. See the prize list and enter to win: http://p.sf.net/sfu/thinkgeek-promo _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users