On Thu, 2011-02-03 at 12:50 -0800, Kirk Wallace wrote: > On Thu, 2011-02-03 at 14:34 -0500, Don Stanley wrote: > > Hi All; > > I am attempting to configure EMC2 10.04.06 to control RPM > > on a 60 HZ AC generator. > > I am hoping to control my Onan with EMC2 someday: > http://www.wallacecompany.com/machine_shop/Onan_5CCK/ >
Oops, I completely missed the point of the question. I think this should work: http://wiki.linuxcnc.org/cgi-bin/emcinfo.pl?Closed_Loop_Spindle_Speed_Control except you will need a sensor for your AC, as you had planned, to feed into the software encoder phase A. A diode bridge could give you 120Hz. Then the encoder velocity output will go into a PID feedback input. The PRM command will go into the PID command input. The PID output will give you the value to feed to the throttle actuator (stepgen, pwmgen). -- Kirk Wallace http://www.wallacecompany.com/machine_shop/ http://www.wallacecompany.com/E45/index.html California, USA ------------------------------------------------------------------------------ The modern datacenter depends on network connectivity to access resources and provide services. The best practices for maximizing a physical server's connectivity to a physical network are well understood - see how these rules translate into the virtual world? http://p.sf.net/sfu/oracle-sfdevnlfb _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users