On 11 August 2011 09:47, Malte RĂ¼temann <[email protected]> wrote:

> How can I change this behavior? Floating or low output after the exit from
> EMC2?

You can't. The 7i43 puts all pins into a high-impedance state when the
internal watchdog bites.
Your external circuits should be designed to kill power in this state
(ie when current stops flowing into the pins). In the case of my 7i43
installation the main motor power contactor drops out in this state.

I think that the Mesa daughter-boards all use negative logic in the same way.

-- 
atp
"Torque wrenches are for the obedience of fools and the guidance of wise men"

------------------------------------------------------------------------------