On Thu, 2011-08-25 at 12:00 -0700, Peter C. Wallace wrote:
... snip
> Dont know Kirks util but extended address should probably be the base address 
> + 0x400 or 0x402 so 0x778 or perhaps 0x77A
... snip

I found a few cards with extended registers where they were not
"supposed" to be, so i made the utility base and extended address
command options independent. I had to use different commands (lspci -v,
dmesg), datasheets or grope-in-the dark to find register addresses.
Someone that knows a thing or two might have a better method.

-- 
Kirk Wallace