On Tue, 2011-09-20 at 19:38 +0300, Andrew wrote: ... snip > It just stops and shows something like "Overvoltage" when connected to PC. ... snip
I've seen this message from my VFD's while setting up dynamic braking where the motor back EMF from motor deceleration (motor becomes more like a generator) back drives the VFD's DC bus beyond the bus maximum voltage. Fitting an appropriate braking resistor or limiting the motor's deceleration usually fixes this. -- Kirk Wallace http://www.wallacecompany.com/machine_shop/ http://www.wallacecompany.com/E45/index.html California, USA ------------------------------------------------------------------------------ All the data continuously generated in your IT infrastructure contains a definitive record of customers, application performance, security threats, fraudulent activity and more. Splunk takes this data and makes sense of it. Business sense. IT sense. Common sense. http://p.sf.net/sfu/splunk-d2dcopy1 _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users