On 4/2/2012 6:24 PM, Oscar Chaides wrote: > Im trying to control a Mitsubishi D700 inverter, i wold like to see > some examples of classicladder controlling some stuff not just the > configuration page of the modbus module, how do i write to the > registers, is it using an assignation block? thanks > > >
You setup a holding register write in the configuration from a %W word to the Modbus register location and you use the ladder assignment to write a value to the %W word. The value you write to the %W shows up in the Modbus register in your connected device. Dave ------------------------------------------------------------------------------ Better than sec? Nothing is better than sec when it comes to monitoring Big Data applications. Try Boundary one-second resolution app monitoring today. Free. http://p.sf.net/sfu/Boundary-dev2dev _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users