On 28 February 2014 15:18, Mark Tucker <[email protected]> wrote:

I have the following in my hal file:-
>
> # This output is on DB25-14 and is currently tied to spindle control
> (M3/M5)
> net Output1 bb_gpio.p8.out-13 => halui.spindle.is-on
>

That's sort-of the wrong pin (it is a userspace tell-tale about spindle
state, not the intended command pin).
use motion.spindle.is-on instead. (and associated pins)
http://www.linuxcnc.org/docs/html/man/man9/motion.9.html


-- 
atp
If you can't fix it, you don't own it.