On 5 December 2014 at 22:31,  <[email protected]> wrote:

> I'm wondering if anyone knows if this ever was implemented.

Yes, there is a pin motion.adaptive-feed:

motion.adaptive-feed IN FLOAT

When adaptive feed is enabled with M52 P1, the commanded velocity is
multiplied by this value. This effect is multiplicative with the
NML-level feed override value and motion.feed-hold.

http://www.linuxcnc.org/docs/html/man/man9/motion.9.html



-- 
atp