> From: [email protected]
> Date: Sat, 18 Apr 2015 13:32:36 -0400
> To: [email protected]
> Subject: Re: [Emc-users] Pncconf with 6i25 and 7i85s in 2.7-pre6
>
> Chris,
>
> I was mistaken. There is indeed a 7i84 in the second combo box. I can
> select that but then I get the wrong designation for the I/O bits. That is,
> I get
> hm2_5i25.0.7i84.0.1.input-00 rather than hm2_5i25.0.7i84.0.0.input-00 (for
> example). I assume that is because, as you say, I cannot select the 7i84 on
> the Connector 3 tab? Or is it just a bug with the numbering (starting at 1
> rather than 0)?
>
> -Tom
>
Tab 3 has the lowest numbered 7i84, tab 2 would be the next. that's how the
firmware describes them.
Pncconf only supports mode 1 and 3 ( question on your other email).
If you need something else then you need to hand edit.