After your suggestion didn’t fix the problem and much debugging it turns out 
that my problem was motor to driver wiring.  The Berger Lahr steppers have 
terminals in a semi-circle labeled 1,2,3,4,5,6,7,8,9,0.  Why would one assume 
that that 0 is 10?  Never assume…as that saying goes :-)

-Tom


> On May 4, 2015, at 8:41 PM, Peter C. Wallace <p...@mesanet.com> wrote:
> 
> Just to make sure its not a current drive issue, can you try connecting the 
> step and dir signals to the 7I85S such that the 7I85S sinks current to drive 
> the OPTO? The current batch of 7I85S's sink current better than source so you 
> would connect the OPTO + to 5V and OPTO- to 7I85S output to get maximum drive


------------------------------------------------------------------------------