I think a fresh thread is in order for this ordeal.

I'm starting at the plug... I dug up some 10-3 SO cord and wired the 
plug and brought that into the left cabinet. Landed the wires on some 
terminal blocks with the DIN rail bolted to the cabinet with star 
washers between the DIN rail and the cabinet. I also scraped the paint 
off the cabinet in that area. Ground terminal blocks surround the 
distribution terminal blocks (two blocks tied together). I'm also making 
a print of the wiring as I go along. So from the distribution blocks the 
240v goes to the VFD filter and the control transformer. I have a second 
filter for the 120v side, should that go just after the control transformer?