On 03/04/2017 10:33 AM, Ben Potter wrote: > Fault: > > On power on, blows fuse/breaker. > > > > 7: Reconnected Z motor to Z drive > > On power up Z ran at maximum speed until I hit e-stop > > > > I'm pretty sure that the Z drive is dead - can anyone suggest any other > tests I should do? > > Hmmm, this is a bit odd. Yes, I think the Z drive is popped, but you should check the Z motor for possible intermittent short to ground. Doesn't make sense that it blows fuses, then you move the drive and put back, and it DOESN'T blow fuses anymore. (Of course, whatever was shorted and blew the fuse may have been burned clear during that short, so it doesn't pop fuses anymore.)
Jon ------------------------------------------------------------------------------ Check out the vibrant tech community on one of the world's most engaging tech sites, SlashDot.org! http://sdm.link/slashdot _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users