On 31 March 2017 at 18:31, Gene Heskett <[email protected]> wrote: > g91.1 (relative I/J/K, is default mode anyway) > g4p.1 (another queue breaker) > G3 X2.6625 Y-0.0000 I-2.6625 J-0.0000 > g90 > o<drill_countersink> endsub
> popup on reload says its a 50% error, regardless of where I put the g91.1 > or g91. If you are trying for a full circle then then (in incremental mode) you want to come back to where you are, so G3 X0 Y0 I-2.6625 J0 -- atp "A motorcycle is a bicycle with a pandemonium attachment and is designed for the especial use of mechanical geniuses, daredevils and lunatics." — George Fitch, Atlanta Constitution Newspaper, 1916 ------------------------------------------------------------------------------ Check out the vibrant tech community on one of the world's most engaging tech sites, Slashdot.org! http://sdm.link/slashdot _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users