There really isn't any issue I know of with using step/dir with encoder 
feedback.  (I currently am with a 5i25/7i85s combo.) And having the encoder 
feedback can be nice for tuning the drives, if the drive's set up software 
doesn't provide any internal "scope" feature.

Todd Zuercher
P. Graham Dunn Inc.
630 Henry Street 
Dalton, Ohio 44618
Phone:  (330)828-2105ext. 2031

-----Original Message-----
From: Marius <[email protected]> 
Sent: Wednesday, December 04, 2019 4:31 AM
To: [email protected]
Subject: [Emc-users] Yaskawa Servopacks with Mesa

Hi

I have been requested to convert a router that has Yaskawa Servo Packs (SGD7S 
with analog and step/dir and encoders) already installed. The installation 
makes use of the STEP/DIR signals currently but with no encoder feedback.

I intend to use the Mesa 7I95 to replace the Chinese controller. My question 
is: Is it ok to use the STEP/DIR feature of this servo pack with encoder 
feedback to LCNC or should I go the Analog route and redo the complete system 
making use of the 7I97.


Regards

Marius