Thanks Chris, yes, I will change the shielding ground to the controller end and isolate the case.
Is it best practice to run the 5v and 12v ‘grounds’ back to the original 24v power supply 0v? > On 9 Oct 2021, at 00:53, Chris Albertson <albertson.ch...@gmail.com> wrote: > > I'll say what Gene said. I'd bet on a groubing issue. The schmatic has an > error, a groubd wire ismissing and also shows random crossing grounds. > Run everything back to the power supply minus post. > > Also you be much better if the sheild was grounded to the controller end. > Never us a machine and it's mounting bolts as grounds. > > > -- > > Chris Albertson > Redondo Beach, California > > _______________________________________________ > Emc-users mailing list > Emc-users@lists.sourceforge.net > https://lists.sourceforge.net/lists/listinfo/emc-users _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users