Am Mon, 21 Jan 2008 11:36:42 +1100 schrieb Carsten Haitzler (The
Rasterman):

> On Sat, 19 Jan 2008 09:07:44 +0100 Andreas Volz <[EMAIL PROTECTED]>
> babbled:
> 
> > Hello,
> > 
> > since some time the temperature module isn't longer working on my
> > system. I don't remember what I've changed. It simply shows "N/A".
> > In .xsession-errors is an entry:
> > 
> > Sending TERM signal
> > to /opt/e17/lib/enlightenment/modules/temperature/linux-gnu-i686/tempget
> > 0 "(null)" 128 (8067).
> > 
> > 
> > Any ideas where I should start to search for the problem? Did I
> > perhaps miss to start a system service?
> 
> a week ago i committed changes to put the temperature polling/reading
> into a separate process - but this just moved the code there and
> should do exactly what it did before - it just has slaved out the
> work to a sub-proc to avoid blocking-reads of temp sensor data that
> seemed to make e "jerky" whenever the temperature was polled (e would
> pause for like 200ms or so whole waiting on the kernel to respond to
> the read). if it changed in the last week then i may have made a
> mistake - otherwise its likely something else. changed kernels?
> modules not loaded?

Maybe I changed a kernel version, but not a relevant jump. See the
output of "sensors" executed by the same user who started e17.

> sensors 
w83697hf-isa-0290
Adapter: ISA adapter
VCore:     +1.52 V  (min =  +0.08 V, max =  +2.11 V)              
+3.3V:     +3.34 V  (min =  +2.05 V, max =  +2.05 V)       ALARM  
+5V:       +4.95 V  (min =  +0.00 V, max =  +0.00 V)       ALARM  
+12V:     +11.55 V  (min =  +3.89 V, max =  +3.89 V)       ALARM  
-12V:      +0.72 V  (min =  -4.38 V, max = -14.75 V)       ALARM  
-5V:       +1.84 V  (min =  -0.48 V, max =  -7.11 V)       ALARM  
V5SB:      +5.48 V  (min =  +0.00 V, max =  +0.97 V)       ALARM  
VBat:      +0.27 V  (min =  +0.10 V, max =  +0.64 V)              
fan1:     2149 RPM  (min =   -1 RPM, div = 4)              ALARM  
fan2:        0 RPM  (min = 5273 RPM, div = 4)              ALARM  
temp1:       +42°C  (high =   +72°C, hyst =    +8°C)   sensor =
diode temp2:     +42.5°C  (high =  +120°C, hyst =  +120°C)   sensor =
diode alarms:   
beep_enable:
          Sound alarm enabled

So the kernel interface seems to work. Perhaps a problem with the API.
I know Gentoo is often bad with unresolved symbols. Perhaps I missed to
recompile a library.

regards
Andreas

-------------------------------------------------------------------------
This SF.net email is sponsored by: Microsoft
Defy all challenges. Microsoft(R) Visual Studio 2008.
http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/
_______________________________________________
enlightenment-users mailing list
enlightenment-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/enlightenment-users

Reply via email to