-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1

Hi,
~  on my system the temperature module does not work either.

Carsten Haitzler (The Rasterman) wrote:
| ...
| 0   SENSOR_TYPE_NONE,
| 1   SENSOR_TYPE_FREEBSD,
| 2   SENSOR_TYPE_OMNIBOOK,
| 3   SENSOR_TYPE_LINUX_MACMINI,
| 4   SENSOR_TYPE_LINUX_I2C,
| 5   SENSOR_TYPE_LINUX_ACPI,
| 6   SENSOR_TYPE_LINUX_PBOOK,
| 7   SENSOR_TYPE_LINUX_INTELCORETEMP
|
| 2nd arg is sensor name (-null- is when no sensor name is
| set). /sys/bus/i2c/devices/ is scanned for sensor names here. the name
is a
| path to the file in /sys/bus/i2c/devices/${DEV}/temp${XXXX}_input file
- - if it
| exists (i.e. a i2c temperature sensor).

I noticed that on my system the temp${XXXX}_input file is in
/sys/bus/pci/devices/${DEV} (neither acpi nor i2c).
Also, the kernel module that is responsible of this is k8temp. My Linux
kernel il 2.6.23.

Regards

- --
Fabio G. Strozzi ~ http://fstrozzi.web.cs.unibo.it