Arun, First of all 1. you are running older code and this is addressed in a newer image. 2. hitting the reset button and then waiting a few minutes (in newer code would address this issue. 3. try rw and enter then save off the config to a server and modify the system line that disables the admin account 4. tftp the new config onto the unit and set the unit to boot with the config 5. upgrade the firmware
Jason On Mon, Sep 10, 2012 at 4:57 PM, Arun Venkataraman <[email protected]> wrote: > Greetings, > > I have a standalone D2 switch running an old firmware release: > > Bp:01.00.40 > Fw:01.00.02.0002 > > I was locked out of the `admin' superuser account after three > tries. I pressed the "password reset" button per the manual, > and duly got the message "Password reset has been pressed" on > the console. However I am still unable to login to the `admin' > account. > > Reviewing the firmware documentation for a later release I saw > that this is a "known bug" (admin account is not re-enabled > after lockout). How do I recover from this condition? Is there > a "reset to factory default" switch or other boot method to > reload the firmware? > > Thanks, > -arun > -- > Arun Venkataraman, Arecibo Observatory/HC3 Box 53995/Arecibo, PR 00612 > [email protected] http://www.naic.edu/~arun (787)878-2612X340 FAX 878-1861 > > --- > To unsubscribe from enterasys, send email to [email protected] with the > body: unsubscribe enterasys [email protected] > -- *Jason Parker* Enterasys Networks Office: 978-684-1468 Email: [email protected] --- To unsubscribe from enterasys, send email to [email protected] with the body: unsubscribe enterasys [email protected]