please i want to find out if enterasys switches and routers have a virtual lab like cisco GNS3 lab. please anybody have any idea, please help me with link.thank
On Tue, Nov 4, 2014 at 2:21 PM, Nick Allen <[email protected]> wrote: > Hi, > > Upgraded our remaining C2's to the last firmware ever made for those > switches: 05.02.18.0002 > This was in order to fix the bug where putty would kill the session if too > much data scrolled by (e.g. show config) > > Well it fixed that bug but now when I authenticate via RADIUS, every time, > authentication fails on the first attempt and succeeds on the second. > > The RADIUS server shows successful authentication both times - identical > events and no indication of any failures. > > I know the C2's are end of life and therefore no longer supported, but > wondered if, short of turning RADIUS off or downgrading the firmware (which > is an option), if there's any other way to solve. > > *login as: nallen* > *[email protected] <[email protected]>'s password:* > *Login of nallen failed* > *Username:nallen* > *Password:********** > > > *Enterasys SecureStack C2* > *Command Line Interface* > > *Enterasys Networks, Inc.* > *50 Minuteman Rd.* > *Andover, MA 01810-1008 U.S.A.* > > *Phone: +1 978 684 1000 <%2B1%20978%20684%201000>* > *E-mail: [email protected] <[email protected]>* > *WWW: http://www.enterasys.com <http://www.enterasys.com>* > > *(c) Copyright Enterasys Networks, Inc. 2011* > > *Chassis Serial Number: 05371963900K* > *Chassis Firmware Revision: 05.02.18.0002* > > Cheers, > > Nick. > > > This e-mail is intended only for the named person or entity to which it is > addressed and contains valuable business information that is privileged, > confidential and/or otherwise protected from disclosure. If you received this > e-mail in error, any review, use, dissemination, distribution or copying of > this e-mail is strictly prohibited. Please notify us immediately of the error > via e-mail to [email protected] and please delete the e-mail from > your system, retaining no copies in any media. We appreciate your cooperation. > > > - --To unsubscribe from enterasys, send email to [email protected] with > the body: unsubscribe enterasys [email protected] > > -- *JUSTICE A YARO SENIOR TECHNICAL OFFICER I.C.T OFFICES OF PARLIAMENT [email protected] <[email protected]> [email protected] <[email protected]> [email protected] <[email protected]>TEL +233-209024238 +233-2428577 87 ACCRA-GHANA. * --- To unsubscribe from enterasys, send email to [email protected] with the body: unsubscribe enterasys [email protected]