----[Please read http://ercoupers.com/disclaimer.htm before following any
advice in this forum.]----


There was some question of how the field portion of the master switch
worked,
and why the whole circuit looked like it was at ground.

If the attached print is able to be posted, you will see at a glance why
an
ohmmeter
check of the circuit looks like it is grounded.

Our generators use the "A" circuit where the field is supplied from an
internal
connection within the generator, and the regulator points varies the
resistance
to ground.

The master switch simply opens this circuit.  (If wired correctly--I have
seen a lot
of wiring errors in Ercoupes)

Cheers:

Paul
NC2273H

==========================================================================
====
To leave this forum go to: http://ercoupers.com/lists.htm