----[Please read http://ercoupers.com/disclaimer.htm before following any advice in this forum.]----


Checking continuity across the meter with an ohmmeter should have banged it's needle to the stop since the meter is a sensitive movement which is powered only by the current generated by a thermocouple.  If the meter actually moves, the problem is elsewhere.  You can remove the theromocouple  and connect it to the meter with clip leads and rule out any connection or wireing problems.  After connecting the two, put a blow torch flame on the thermocouple till it starts to glow a little.  If the meter moves, the problem is probably a wireing issue.  If not, thermocouples go bad.  Pretty harsh environment.  Bigger blow torch.
Dick
----- Original Message -----
From: Ed Clavel
To: [email protected]
Sent: Saturday, February 26, 2005 6:19 PM
Subject: [COUPERS-TECH] EGT

----[Please read http://ercoupers.com/disclaimer.htm before following any advice in this forum.]----


Is this a great medium or what ?
My EGT instrument quit working. I checked continuity across the instrument and across the thermocouple. I have continuity on both. Is there anyone out there can tell me another way to check the EGT system.
Ed
N3396H from Oregon.
==============================================================================
To leave this forum go to: http://ercoupers.com/lists.htm
Search the archives on http://escribe.com/aviation/coupers-tech/



==============================================================================
To leave this forum go to: http://ercoupers.com/lists.htm
Search the archives on http://escribe.com/aviation/coupers-tech/



Reply via email to