----[Please read http://ercoupers.com/disclaimer.htm before following any advice in this forum.]----
At 08:26 AM 6/4/2005, Russell Whetton wrote: >I need to "flash" my regulator.\ Actually, it's the field coils of the generator that need to be flashed. the purpose is to induce a little residual magnetism in the field coil poles so the generator can self excite. The engine does not have to be running; for that matter, the generator doesn't even need to be installed. Being an alternator kind of guy, I have to reinvent the wheel each time, but basically, figure out if the regulator is controlling the hot or ground side of the field then either touch the field wire to hot or ground for a few seconds, 4 or 5 times. More information is available on the Zeftronics web site under troubleshooting. John Cooper Skyport Services PO Box 249 4996 Delaware Tnpk Rensselaerville, NY 12147 518 797-3064 Fax 518 797-3865 ========================================================================== ==== To leave this forum go to: http://ercoupers.com/lists.htm Search the archives on http://escribe.com/aviation/coupers-tech/
<<attachment: winmail.dat>>