At 08:51 AM 4/29/2006, Randy Hougham wrote:
Mine did not have the flex hose runnig to it. Does anyone know if that was on the '46 415-C?

It may very well have been omitted. This is the case for a lot of different aircraft types of the same era. However, the Continental documentation specifies a minimum pressure differential across the generator for cooling purposes. Unlike an alternator, the generator does not have an internal fan, thus requires forced air to cool. that said, a 13 amp generator likely can't generate enough heat to be a problem...

Later models do specify a blast tube for the generator, pn 40704-4


John Cooper, A&P