We have an Ercoupe here without the header tank but it does not draw 
from both tanks at the same time. It has a left, right and off but it 
does not have plugs in the caps. This is also on a 337. I used to 
have an Ercoupe with the 15 gallon wing tanks and no header. It did 
draw from both wigs at the same time and also did not have plugs in 
the caps.

Some people consider the center tank a safety feature and some people 
consider it a safety hazard.

Kevin

--- In [email protected], "Hartmut Beil" <[EMAIL PROTECTED]> wrote:
>
> Bill.
> 
> First I have to wonder how the 337 got approval. We all are 
considering the header tank as the big reserve and safety item in 
case of a fuel pump failure.
> 
> Second. My fuel system is of the later plumbing style with a return 
line into both wing tanks. From my understand din, I can use non 
vented fuel caps. So I bought me a set and flew with it. I 
experienced the same thing like you do.
> 
> One tank stays full or almost full. No good I thought and put the 
vented caps back on. Problem solved.
> 
> Hartmut
> 
> 
> 
> 
> 
>   ----- Original Message ----- 
>   From: [EMAIL PROTECTED] 
>   To: [email protected] 
>   Sent: Sunday, November 04, 2007 1:39 PM
>   Subject: [ercoupe-tech] Fuel caps.
> 
> 
> 
>   My coupe has had the center tank removed and is set up to operate 
from both wing tanks.  This was done by a previous owner and I have 
checked the system as per information in the 337 done when the 
modification was completed and all operates satisfactory.  The system 
works great for me as all my flights are of short duration.  
> 
>   My problem is with the fuel caps which are the type originally 
used with the center tank.  Plastic tube & float which can only read 
the top 4 1/2 gal in each 9 gal tank.  This limits how long I fly 
each leg as I will not fly with my fuel gauge reading "E" even when I 
know it only reads half of the tank quantity.  The previous owner 
advised me to make sure that the fuel cap vents are pointing forward 
and that the vents must be "Plugged".  Each seems to have a small 
wooden plug in it.  It all has worked fine for the year that I have 
owned the coupe however the last few flights I have noticed that I 
seem to be using fuel from the left tank only in flight.  The right 
gauge stays full and the left comes down as you fly.  As soon as you 
land and do not have the airflow the level of the tanks equals and 
the gauges read the same.  My first idea was to swap caps but I find 
that neither will line up forward in the opposite tank.  
> 
>   Before I start the process of trial and error I wonder if anyone 
else has had experience with this situation.  Do the vents need to be 
plugged?  If so, what is best to use as a match stick seems less than 
professional. Are these the best caps to use in this configuration 
bearing in mind that I have no other fuel gauge?  Any other ideas or 
advice would be appreciated.
> 
>   Bill Farthing
>