Folks:
I miss-spoke the other day. The fuel pump used by Skyport in the O200 STC and also in the 30 gallon fuel system does NOT have a check valve in it. However, one should not be necessary as the design of the fuel inlet to the header tank is supposed to prevent fuel from flowing backwards in order to prevent said fuel from fueling an engine compartment fire should the line burn through. This is accomplished by placing the inlet higher in the tank than the overflow, or by putting a standpipe inside the tank to accomplish the same thing in the case where the line enters the bottom of the tank. John Cooper Skyport Services 518 797-3064 www.skyportservices.net _____ From: [email protected] [mailto:[EMAIL PROTECTED] On Behalf Of [EMAIL PROTECTED] Sent: Sunday, February 03, 2008 9:21 PM To: [email protected] Subject: [ercoupe-tech] Re: Alon Fuel System Does anyone out there have a good copy of the Alon A2 fuel system piping layout that is a little more understandable then the one in the owners manual, It is a little confusing and unclear exactly where some of the lines go. My problem is that all the fuel in the header tank is draining back into the wingtanks.