Hey Mac: I should have mentioned in my previous email that one item to  
check would be the completion of AD 47-20-3. I have found several Ercoupes that 
 were not in compliance. I suspect that it was complied with long ago, and 
then  the fuel pump was changed, and the AD was not complied with a second 
time. I  think a big part of the problem is/was that the AD specified a  
specific part number of fuel pump. When a new or rebuilt fuel pump was  
purchased, the part number was different, so the person installing the pump  
would 
not comply with the AD. It makes sense to me to comply with the change  even 
though you have a different fuel pump part number. That AD required the  
installation of the fitting containing the 1/16 hole, and rotation of the top 
of  the pump 2 screw holes which changed the location and routing of the fuel 
pump  lines.