OK, now THAT makes a lot of sense, had not even thought that someone would come 
up with such a shoddy solution.  I intend to disassemble it to see just what 
the heck was going on.

--- In [email protected], John Cooper <j...@...> wrote:
>
> The master switch is a simple DPST switch. There is no difference 
> between the two sets of contacts.  My guess is someone switched the 
> contacts on yours when the load carrying set started to fail.  Now they 
> are failing to carry the generator field current.  Ordinarily, the 
> generator set should long outlast the load set.
> 
> The Alpha STC is a good solution, but the mechanical switch lets you go 
> even if the battery is dead.  It'll hold up well as long as you don't 
> switch it while it's carrying a load, especially, never switch it while 
> the starter is engaged!
> 
> John
>


Reply via email to