On 4/24/2010 12:50 PM, craig wrote:
> The pump outlet to the nose tank is too low on the tank- this puts fuel 
> pressure on the pump valves when the pump is idle.
>    
This cannot be correct. If it were, you would have fuel flow through the 
firewall with no way to stop it, a clear violation of the certification 
requirements.  Could it be that you have the inlet and the overflow 
reversed?  If not, then something is amiss.

-- 
John Cooper