At 04:10 PM 06/14/2002, John Carmack wrote: >>We tried those tanks, be warned that the plugs that thread into the >>flanges serve as a structural fuse at about 250 psi (Doomp! said the >>hydrotest) by stripping out the threads in the polyethylene tank liner. >>That tank is now a pretty pipe stand... > >Thanks, we'll keep that in mind. They have flange mounts starting at the >100 gallon sizes, which could be made strong enough to reach the strength >of the vessel.
This is outstanding. A well-heeled amateur being helped by a professional on a list run by broke amateurs - John, is this the kind of synergy you've been looking for? :-) -R -- No electrons were harmed in the creation of this message PETE - People for the Ethical Treatment of Electrons Randall Clague [EMAIL PROTECTED] _______________________________________________ ERPS-list mailing list [EMAIL PROTECTED] http://lists.erps.org/mailman/listinfo/erps-list