Kevin Bollinger,

Am Donnerstag, 5. September 2002 um 07:02 you wrote:

kb>    For your information, 20lb/in^2/min is a "standard design value" many
kb> engines used much higher loadings up to 200lb/in^2/min !!!! , The British
kb> Gamma engines used 50-60 lb/in^2/min.in their silver screen packs.

kb> Kevin Bollinger

To calculate the loading of a catalyst what surface has to be used?
It`s the geometric surface of the totality of the screen stack or
the effective surface of the silver in the catalyst?

Hans Ulrich Ammann
mailto:[EMAIL PROTECTED]
http://www.spl.ch

_______________________________________________
ERPS-list mailing list
[EMAIL PROTECTED]
http://lists.erps.org/mailman/listinfo/erps-list