At 10:10 PM 9/14/2004, David Masten wrote:
Since it has been awhile...

We figured out the serial problem.

Good work.

I've had endless problems over the years with serial ports. A lot has turned out to be crappy serial software in Windows (like HyperTerm, HyperAccess is better...a little).

I also had problems with Siemens integrated UART chips on Sun systems. On full auto they get overflows when talking to a Windows machine, the Siemens chips don't like getting 17 extra characters after they set flow control to STOP.


---------- Jerry Durand Durand Interstellar, Inc. 219 Oak Wood Way Los Gatos, California 95032-2523 USA tel: +1 408 356-3886 fax: +1 408 356-4659 web: www.interstellar.com pgp: 45A2 0A52 1D56 70C2 B865 9D5C 83F2 2112 04CE 2B54


_______________________________________________ ERPS-list mailing list [EMAIL PROTECTED] http://lists.erps.org/mailman/listinfo/erps-list