Dear all, I have a problem with the data acquisition in TestManager.
First of all, my specs: etherlab 1.2-rc10 My linux version is: openSUSE 11.2 "Emerald" - Kernel \r My RTAI version is 3.7.1 Matlab is R2009b, Simulink version is: v 7.4 and RTW is: v 7.4 Now, I have just learned through experimenting that the "fundamental sample time" in the configuration Parameters in my Simulink model i have built, is actually the maximal sampling frequency that will appear in TestManager , in the Data Transfer option for every channel. This is quite a find for me because nobody explains this stuff anywhere! The Testmanager documentation is in German (lol!), all I have is an english translated documentation for TestManager 3.4 which is not good at all. Ok, now that I finnaly can sample at the sampling rate I want, next step is to choose the accuracy for each channel, right? Not quite! Well it turns out that whatever accuracy i put in there (3,4...9) and then trying to acquire some channels using the Scope, and then exporting the acquired data in Matlab-format, Testmanager never respects/maintains the accuracy number i put in there. For example if i select 1000Hz sampling time + 3 accuracy (3 digits after the "." in the number) for a channel, then after exporting, Testmanager just spits out data @ 1000Hz with 16 floating point digits after the "." in the number. This of course has serious impact because for 10 seconds of data i get files of 11-20 mb for 1 channel -> aka not good! May I ask you: "what is going on?" because I have no idea. Thank you for your time! Alex M.
_______________________________________________ etherlab-users mailing list etherlab-users@etherlab.org http://lists.etherlab.org/mailman/listinfo/etherlab-users