Hello,

I probably misunderstood something, but I take these inputs from the Beckhoff 
EL2522 XML file:

<OpMode>
    <Name>DC</Name>
    <Desc>DC-Synchron</Desc>
    <AssignActivate>#x700</AssignActivate>
    <CycleTimeSync0 Factor="1">0</CycleTimeSync0>
    <ShiftTimeSync0 Input="0">0</ShiftTimeSync0>
    <CycleTimeSync1 Factor="1">0</CycleTimeSync1>
    <ShiftTimeSync1>140000</ShiftTimeSync1>
</OpMode>

So I assumed that the sync1 shift time should be configured somewhere. 

Philippe Leuba

> On 13 Mar 2017, at 00:01, Gavin Lambert <gav...@compacsort.com> wrote:
> 
> According to the documentation that I can find for the EL2522, it only uses
> SYNC0, so I'm not sure what you're referring to here.  (Granted I only
> glanced through so I might have missed something.)
_______________________________________________
etherlab-users mailing list
etherlab-users@etherlab.org
http://lists.etherlab.org/mailman/listinfo/etherlab-users

Reply via email to