On 16 Aug 2021 at 14:40, Robert Bruninga via EV wrote:

> Though, I bet they have sensing at the 24 and 36v taps to control
> charging and those taps will not exist. 

No sensing - they're not that sophisticated!

The smaller tractors - ER8-36, E8, E10 - don't have a lift or lights, so 
it's not a problem.  

The large frame tractors have battery taps for the lights (12v) and for the 
electric front implement lift (18v).  The lights can be swapped out for LEDs 
to run at the full voltage.  I run my lift at 24v and I know of at least one 
person who has it at 36v (that might be a bit high).  You could run a 42v 
system with a tap at 16.8v or possibly 25.2v for the lift.