https://bugs.exim.org/show_bug.cgi?id=400
Lena <[email protected]> changed: What |Removed |Added ---------------------------------------------------------------------------- Resolution|FIXED |--- Status|RESOLVED |REOPENED --- Comment #3 from Lena <[email protected]> --- > This patch shuts down the sending side of the network socket after all the > data > has been sent. This is a clear signal to the remote server that it should > process the data and then close the socket. Some HTTP servers break connection entirely at such sending side shutdown. For example tinyurl.com and some other URL shorteners. > I have tested this with the sqlgrey daemon. I think it is unlikely to cause > problems for existing configs, but you may want to make it an optional feature > anyway. I propose two alternative patches: 1. https://bugs.exim.org/attachment.cgi?id=979 Do not shutdown if port 80. 2. https://bugs.exim.org/attachment.cgi?id=980 Do not shutdown if timeout (third argument of readsocket item) is specified as a negative number. Absolute value (without the munus) is used as timeout. -- You are receiving this mail because: You are the QA Contact for the bug. -- ## List details at https://lists.exim.org/mailman/listinfo/exim-dev Exim details at http://www.exim.org/ ##