[This message was posted by Rolf Andersson of Pantor Engineering 
<[email protected]> to the "FAST Protocol" discussion forum at 
http://fixprotocol.org/discuss/46. You can reply to it on-line at 
http://fixprotocol.org/discuss/read/813be924 - PLEASE DO NOT REPLY BY MAIL.]

Michael,

the length field occupies a bit in the message pmap if there is an operator 
specified for the length field of the sequence.

I don't have the FAST spec in front of me but IIRC section 6.2.5 contains info 
about sequences.

I can check more closely if you send me the template you are using.

/Rolf

> Rolf,
> 
> I want to know if the first bit of PMAP for sequence field indicate
> the presence of length field or not. Is there related information
> in the spec?
> 
> Thanks Michael


[You can unsubscribe from this discussion group by sending a message to 
mailto:[email protected]]

--~--~---------~--~----~------------~-------~--~----~
You received this message because you are subscribed to the Google Groups 
"Financial Information eXchange" group.
To post to this group, send email to [email protected]
To unsubscribe from this group, send email to 
[email protected]
For more options, visit this group at 
http://groups.google.com/group/FIX-Protocol?hl=en
-~----------~----~----~----~------~----~------~--~---

Reply via email to