On Fri, Mar 12, 2010 at 12:05 AM, [email protected] <[email protected]> wrote: > "Theoretically", it starts automatically when an APT start sequence is > detected. I do not know how to enhance the process at the moent. Maybe a > better filter. The APT frequency has some margin, but if it is too large, it > starts decoding each time 300 hz is detected in noise. So, the method should > be refined.
Instead of comparing the 300Hz power to a constant threshold, compare it to the power in nearby bins in order to determine S:N power at 300Hz. That should be self-adjusting. -- 73 de Brian, WB6RQN/J79BPL _______________________________________________ fldigi-alpha mailing list [email protected] https://lists.berlios.de/mailman/listinfo/fldigi-alpha