On Mon, 8 Jun 2009, David Zhang wrote:

> http://developers.sun.com/solaris/articles/scsi_disk_fma2.html
> It could give us steps to reproduce what was happened on your ssd disk.
>
> With fmdump -eV, we can find what ereport cause this issue, and do
> further analyze.

fmdump -V -u <uuid> worked fine, output at the bottom. However, the version
of fmdump in S10 doesn't have the '-n' option?

r...@ike ~ # fmdump -ev -n ena=0xc7d80697a6402c01
fmdump: illegal option -- n

Is that something new in OpenSolaris? Any way under S10 to get the same
info?

Thanks...

r...@ike ~ # fmdump -V -u 16e83c34-b478-60c0-964d-e9cbd7bf4422
TIME                 UUID                                 SUNW-MSG-ID
Jun 04 17:45:55.9791 16e83c34-b478-60c0-964d-e9cbd7bf4422 DISK-8000-2J

  TIME                 CLASS                                 ENA
  Jun 04 17:45:53.7297 ereport.io.scsi.disk.self-test-failure
0xc7d80697a6402c01

nvlist version: 0
        version = 0x0
        class = list.suspect
        uuid = 16e83c34-b478-60c0-964d-e9cbd7bf4422
        code = DISK-8000-2J
        diag-time = 1244162755 947776
        de = (embedded nvlist)
        nvlist version: 0
                version = 0x0
                scheme = fmd
                authority = (embedded nvlist)
                nvlist version: 0
                        version = 0x0
                        product-id = Sun Fire X4500
                        chassis-id = 0819AMT059
                        server-id = ike
                (end authority)

                mod-name = eft
                mod-version = 1.16
        (end de)

        fault-list-sz = 0x1
        fault-list = (array of embedded nvlists)
        (start fault-list[0])
        nvlist version: 0
                version = 0x0
                class = fault.io.disk.self-test-failure
                certainty = 0x64
                asru = (embedded nvlist)
                nvlist version: 0
                        version = 0x0
                        scheme = dev
                        device-path = 
/p...@2,0/pci1022,7...@8/pci11ab,1...@1/d...@4,0
                        devid = 
id1,s...@sata_____ssdsa2sh032g1gn___cvem902600j6032hgn
                (end asru)

                fru = (embedded nvlist)
                nvlist version: 0
                        version = 0x0
                        scheme = hc
                        hc-root =
                        serial = CVEM902600J6032HGN
                        part = SSDSA2SH032G1GN-INTEL
                        revision = 045C8626
                        authority = (embedded nvlist)
                        nvlist version: 0
                                product-id = Sun-Fire-X4500
                                chassis-id = 0819AMT059
                                server-id = ike
                        (end authority)

                        hc-list-sz = 0x2
                        hc-list = (array of embedded nvlists)
                        (start hc-list[0])
                        nvlist version: 0
                                hc-name = bay
                                hc-id = 5
                        (end hc-list[0])
                        (start hc-list[1])
                        nvlist version: 0
                                hc-name = disk
                                hc-id = 0
                        (end hc-list[1])

                (end fru)

                resource = (embedded nvlist)
                nvlist version: 0
                        version = 0x0
                        scheme = hc
                        hc-root =
                        serial = CVEM902600J6032HGN
                        part = SSDSA2SH032G1GN-INTEL
                        revision = 045C8626
                        authority = (embedded nvlist)
                        nvlist version: 0
                                product-id = Sun-Fire-X4500
                                chassis-id = 0819AMT059
                                server-id = ike
                        (end authority)

                        hc-list-sz = 0x2
                        hc-list = (array of embedded nvlists)
                        (start hc-list[0])
                        nvlist version: 0
                                hc-name = bay
                                hc-id = 5
                        (end hc-list[0])
                        (start hc-list[1])
                        nvlist version: 0
                                hc-name = disk
                                hc-id = 0
                        (end hc-list[1])

                (end resource)

                location = HD_ID_5
        (end fault-list[0])

        fault-status = 0x1
        __ttl = 0x1
        __tod = 0x4a286ac3 0x3a5d5c48



-- 
Paul B. Henson  |  (909) 979-6361  |  http://www.csupomona.edu/~henson/
Operating Systems and Network Analyst  |  hen...@csupomona.edu
California State Polytechnic University  |  Pomona CA 91768
_______________________________________________
fm-discuss mailing list
fm-discuss@opensolaris.org