On Mon, 8 Jun 2009, David Zhang wrote: > http://developers.sun.com/solaris/articles/scsi_disk_fma2.html > It could give us steps to reproduce what was happened on your ssd disk. > > With fmdump -eV, we can find what ereport cause this issue, and do > further analyze.
fmdump -V -u <uuid> worked fine, output at the bottom. However, the version of fmdump in S10 doesn't have the '-n' option? r...@ike ~ # fmdump -ev -n ena=0xc7d80697a6402c01 fmdump: illegal option -- n Is that something new in OpenSolaris? Any way under S10 to get the same info? Thanks... r...@ike ~ # fmdump -V -u 16e83c34-b478-60c0-964d-e9cbd7bf4422 TIME UUID SUNW-MSG-ID Jun 04 17:45:55.9791 16e83c34-b478-60c0-964d-e9cbd7bf4422 DISK-8000-2J TIME CLASS ENA Jun 04 17:45:53.7297 ereport.io.scsi.disk.self-test-failure 0xc7d80697a6402c01 nvlist version: 0 version = 0x0 class = list.suspect uuid = 16e83c34-b478-60c0-964d-e9cbd7bf4422 code = DISK-8000-2J diag-time = 1244162755 947776 de = (embedded nvlist) nvlist version: 0 version = 0x0 scheme = fmd authority = (embedded nvlist) nvlist version: 0 version = 0x0 product-id = Sun Fire X4500 chassis-id = 0819AMT059 server-id = ike (end authority) mod-name = eft mod-version = 1.16 (end de) fault-list-sz = 0x1 fault-list = (array of embedded nvlists) (start fault-list[0]) nvlist version: 0 version = 0x0 class = fault.io.disk.self-test-failure certainty = 0x64 asru = (embedded nvlist) nvlist version: 0 version = 0x0 scheme = dev device-path = /p...@2,0/pci1022,7...@8/pci11ab,1...@1/d...@4,0 devid = id1,s...@sata_____ssdsa2sh032g1gn___cvem902600j6032hgn (end asru) fru = (embedded nvlist) nvlist version: 0 version = 0x0 scheme = hc hc-root = serial = CVEM902600J6032HGN part = SSDSA2SH032G1GN-INTEL revision = 045C8626 authority = (embedded nvlist) nvlist version: 0 product-id = Sun-Fire-X4500 chassis-id = 0819AMT059 server-id = ike (end authority) hc-list-sz = 0x2 hc-list = (array of embedded nvlists) (start hc-list[0]) nvlist version: 0 hc-name = bay hc-id = 5 (end hc-list[0]) (start hc-list[1]) nvlist version: 0 hc-name = disk hc-id = 0 (end hc-list[1]) (end fru) resource = (embedded nvlist) nvlist version: 0 version = 0x0 scheme = hc hc-root = serial = CVEM902600J6032HGN part = SSDSA2SH032G1GN-INTEL revision = 045C8626 authority = (embedded nvlist) nvlist version: 0 product-id = Sun-Fire-X4500 chassis-id = 0819AMT059 server-id = ike (end authority) hc-list-sz = 0x2 hc-list = (array of embedded nvlists) (start hc-list[0]) nvlist version: 0 hc-name = bay hc-id = 5 (end hc-list[0]) (start hc-list[1]) nvlist version: 0 hc-name = disk hc-id = 0 (end hc-list[1]) (end resource) location = HD_ID_5 (end fault-list[0]) fault-status = 0x1 __ttl = 0x1 __tod = 0x4a286ac3 0x3a5d5c48 -- Paul B. Henson | (909) 979-6361 | http://www.csupomona.edu/~henson/ Operating Systems and Network Analyst | hen...@csupomona.edu California State Polytechnic University | Pomona CA 91768 _______________________________________________ fm-discuss mailing list fm-discuss@opensolaris.org