Sorry, I noticed I used the subject from the preivious message. --- Clay Wise <[EMAIL PROTECTED]> wrote:
> I have a question about the CHANGEDETECTOR > Transformer. I have been receiving this error when > I > am trying to take the data out of SDE and place the > results in any other format (SDE or PGDB). > > 2005-10-31 14:23:43| 6.4| 0.0|ERROR |A field type > of 'No' was specified, which is not valid. Please > check the documentation on the Geodatabase > Reader/Writer for information on valid field types. > > I am looking for the online information on data > types > that the transformer will support, and having a hard > time. The original and revised inputs have these > data > types: > > Integer > Char > Double > > Thanks, > Clay > > > > --- mark2atsafe <[EMAIL PROTECTED]> wrote: > > > Hi /Nisse, > > Well the "Meet-Interior-Disjoint" predicate seems > to > > work OK with the > > data you've supplied. Of course the ports need to > be > > switched round > > (you want to keep failed features, not passed). > > > > The documentation for the SpatialFilterFactory is > > more detailed than > > the transformer docs. For "meet-interior-disjoint" > > it says that > > "...one instance where MEET succeeds and this > > predicate does not is > > when a point lies on a polygon's border." > > > > So change 'disjoint' to 'meet_interior_disjoint' > and > > give that a try. > > I hope this helps. Don't know if it works for all > > your data but it > > certainly seems to work on the workspace you sent. > > > > Regards, > > > > Mark > > > ---------------------------------------------------------------------- > > Mark Ireland, Product Support Engineer > > Safe Software Inc. Surrey, BC, CANADA > > [EMAIL PROTECTED] http://www.safe.com > > Solutions for Spatial Data Translation, > Distribution > > and Access > > > ---------------------------------------------------------------------- > > > > > > --- In [email protected], Dahlsten Nils-Erik > > <[EMAIL PROTECTED]> wrote: > > > > > > Hi all. > > > > > > How do I set the filters in FME (I've tried them > > all I think) to NOT > > include > > > a line that touches (ends against) an are. > > > > > > Look at the attached Workspace and I think you > see > > what I mean. I've > > put a > > > "desc" attribute that tells wether the object > > should be treated as > > inside or > > > outside. > > > > > > Thanks. > > > > > > /Nisse > > > > > > PS. I have a lot of data to do these tests on, > so > > I'd prefer a "slim" > > > solution. DS > > > > > > > > > Nils-Erik Dahlsten > > > Lantmäteriverket/Metria > > > 801 82 Gävle > > > Besöksadress: Lantmäterigatan 2 > > > 026-633019 (026-633000) > > > [EMAIL PROTECTED] > > <mailto:[EMAIL PROTECTED]> > > > www.lantmateriet.se/metria > > <http://www.lantmateriet.se/metria/index.asp> > > > > > > > > > > > > > > > > > Get the maximum benefit from your FME, FME > Objects, > > or SpatialDirect via our Professional Services > team. > > Visit www.safe.com/services for details. > > Yahoo! Groups Links > > > > > > [EMAIL PROTECTED] > > > > > > > > > > > > > > > > > __________________________________ > Yahoo! FareChase: Search multiple travel sites in > one click. > http://farechase.yahoo.com > > > > > Get the maximum benefit from your FME, FME Objects, > or SpatialDirect via our Professional Services team. > Visit www.safe.com/services for details. > Yahoo! Groups Links > > > [EMAIL PROTECTED] > > > > > __________________________________ Yahoo! Mail - PC Magazine Editors' Choice 2005 http://mail.yahoo.com Get the maximum benefit from your FME, FME Objects, or SpatialDirect via our Professional Services team. Visit www.safe.com/services for details. Yahoo! Groups Links <*> To visit your group on the web, go to: http://groups.yahoo.com/group/fme/ <*> To unsubscribe from this group, send an email to: [EMAIL PROTECTED] <*> Your use of Yahoo! Groups is subject to: http://docs.yahoo.com/info/terms/