Cliff Fogle wrote:
> Have you first tried the following from the "server port 153" config, thereby
> setting 153 to be udp protocol dns?:
>
>
> [EMAIL PROTECTED](config-port-153)#udp keepalive
> DECIMAL Number
> protocol protocol used for keepalive
> [EMAIL PROTECTED](config-port-153)#udp keepalive proto
> dns
> [EMAIL PROTECTED](config-port-153)#udp keepalive proto dns
Yep, it's in the example I sent in the mail. Foundry simply doesn't
support using the state of the master port for UDP ports...
best regards,
michael
From [EMAIL PROTECTED] Mon Nov 22 16:49:06 2004
From: [EMAIL PROTECTED] (Cliff Albert)
Date: Mon Nov 22 16:49:09 2004
Subject: [f-nsp] HP 9300 series compatibility with Foundry BigIron 4K
Message-ID: <[EMAIL PROTECTED]>
Hi,
We own a HP Procurve 9304 series, which looks like it's a Foundry
BigIron 4K relabeled edition (even our HP support contact tells so).
Has anyone had any experience on exchanging modules between these two ?
I know powersupplies work because we are currently running or 9304 on
a NetIron powersupply and an HP powersupply.
Currently the 9304 runs on an EP blade which corresponds to jetcore blades.
Anyone tried this ? Or has substantiated evidence that this works ?
Thanks in advance,
--
Cliff Albert <[EMAIL PROTECTED]>
From [EMAIL PROTECTED] Mon Nov 22 16:59:32 2004
From: [EMAIL PROTECTED] (Jonas Frey)
Date: Mon Nov 22 16:59:36 2004
Subject: [f-nsp] HP 9300 series compatibility with Foundry BigIron 4K
In-Reply-To: <[EMAIL PROTECTED]>
References: <[EMAIL PROTECTED]>
Message-ID: <[EMAIL PROTECTED]>
Hi,
yes this is correct. HP however gets its own firmware from foundry which
calls everything HP and gets their module names. However you can use
foundry modules without problems. You can even flash the firmware to a
bigiron one and get more features/newer firmware.
Regards,
Jonas
On Mon, 2004-11-22 at 22:49, Cliff Albert wrote:
> Hi,
>
> We own a HP Procurve 9304 series, which looks like it's a Foundry
>
> BigIron 4K relabeled edition (even our HP support contact tells so).
>
>
>
> Has anyone had any experience on exchanging modules between these two ?
> I know powersupplies work because we are currently running or 9304 on
> a NetIron powersupply and an HP powersupply.
>
> Currently the 9304 runs on an EP blade which corresponds to jetcore blades.
>
> Anyone tried this ? Or has substantiated evidence that this works ?
>
> Thanks in advance,
>
>