Colleagues, hi again I need an MLX-8 with redundant route processor, switch fabric and power; seven 10Gx4 linecards and single 20-port GE/SFP.
Whether the following spec correct and confirm these requirements? - NI-MLX-8-AC (NI MLX 8-SLOT CHASSIS, 1 MR, 2 SF3, 2 AC) :: 1 NI-MLX-MR (NI MLX MANAGEMENT MODULE) :: 1 NI-MLX-10GX4 (NI MLX 4-PORT 10GE) :: 7 NI-MLX-1GX20-SFP (NetIron MLX Series 20-port FE/GE (100/1000)) :: 1 Also, whether these are correct transceivers for TGE and GE linecards? - 10G-XFP-LR (OPTIC, 10GBE, LR, XFP, SMF, LC CONNECTOR) E1MG-LX (1000BaseLX SFP optic SMF, LC connector) and is it mandatory to use Brocade's own transceivers (as Cisco requires) or it's ok to use anything? Thank you -- /doka /*-- http://doka-ua.blogspot.com/ --*/
_______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp