Hi,

> Colleagues, hi again
> 
> I need an MLX-8 with redundant route processor, switch fabric and power; 
> seven 10Gx4 linecards and single 20-port GE/SFP.
> 
> Whether the following spec correct and confirm these requirements? -
> 
> NI-MLX-8-AC (NI MLX 8-SLOT CHASSIS, 1 MR, 2 SF3, 2 AC) :: 1
> NI-MLX-MR (NI MLX MANAGEMENT MODULE) :: 1
> NI-MLX-10GX4 (NI MLX 4-PORT 10GE) :: 7
> NI-MLX-1GX20-SFP (NetIron MLX Series 20-port FE/GE (100/1000)) :: 1
> 
> Also, whether these are correct transceivers for TGE and GE linecards? -
> 
> 10G-XFP-LR (OPTIC, 10GBE, LR, XFP, SMF, LC CONNECTOR)
> E1MG-LX (1000BaseLX SFP optic SMF, LC connector)
> 
> and is it mandatory to use Brocade's own transceivers (as Cisco requires) or 
> it's ok to use anything?

All correct, and no, you dont have to use Brocade's own receivers.

Best regards,

Michiel Muhlenbaumer
Atrato IP Networks




_______________________________________________
foundry-nsp mailing list
[email protected]
http://puck.nether.net/mailman/listinfo/foundry-nsp

Reply via email to