On Sun, Oct 3, 2010 at 8:16 PM, Youssef Ghorbal <[email protected]> wrote: > Hello, > > On a MLX-16, one of the Switch Fabric suffer from a very slow CAM > lookup. When I issue a command like : > $> show cam ip 2/18 192.168.90.0 255.255.255.0 > It takes nearly 2/3 seconds to have the prompt back. When it's > instant on other modules. I don't have the problem on the same module > when it comes to ethernet CAM. > This CAM lookup issue increases the network latency by a factor of > 30. Ping RTT reach 30ms when it was 1ms in the past. > > The Line Processor (LP) of the module seems to be beasy (beasier than > the other modules) > LP-2#show cpu-utilization > ... Usage average in the last 1 second - 65 ... > last 1 second utilization = 65 > last 5 seconds utilization = 63 > last 1 minute utilization = 66 > last 5 minutes utilization = 66 > > on other LP : > LP-1#show cpu-utilization > ... Usage average in the last 1 second - 1 ... > last 1 second utilization = 1 > last 5 seconds utilization = 1 > last 1 minute utilization = 1 > last 5 minutes utilization = 1
I'll answer myself. After some digging with the Brocade support it happens to be an ICMP redirect issue. We are in a situation of a "single armed router" and The LP spends it's time sending/generating ICMP redirects. Plus, the issue have already been reported and treated on this list (a while back) http://osdir.com/ml/network.nsp.foundry/2006-12/msg00008.html "$> no ip icmp redirect " did the trick for us. Thanks all for your support. Youssef _______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp