Hi

I was working on the same config.
From what I've been able to get in place you'll need a static route in
order to get the vc/vll up. It stands as your "IGP". I couldn't get
things to work sending the /32s through BGP even though RFC 3107 is
suppported on both sides. I put in a static route on each side that
pointed to the loopback address that included both the next-hop
interface and the next-hop IP address.
My solution was to disable the default "Inter AS Filter".

router mpls
 policy
  no filter-inter-as-routes


Regards
 Erich