Hi I was working on the same config.
From what I've been able to get in place you'll need a static route in order to get the vc/vll up. It stands as your "IGP". I couldn't get things to work sending the /32s through BGP even though RFC 3107 is suppported on both sides. I put in a static route on each side that pointed to the loopback address that included both the next-hop interface and the next-hop IP address.
My solution was to disable the default "Inter AS Filter".
router mpls policy no filter-inter-as-routes Regards Erich _______________________________________________ foundry-nsp mailing list [email protected] http://puck.nether.net/mailman/listinfo/foundry-nsp