2012/2/25 Eugene Grosbein <[email protected]>: > 25.02.2012 00:14, Eugene Grosbein пишет: >> This problem occurs only when net.isr.direct=0/net.isr.direct_force=0. >> And only when lagg1 has both ports up and running. And when I use oversized >> pings. >> At the same time, transit oversized pings go through this BRAS just fine, >> no packet loss at all. > > Running two copies of tcpdump for igb0 and igb1 simultaneously, > I see that fragments of the same ICMP echo-reply packet encapsulated within > PPPoE > frame always go out through different ports of lagg1. Even when they arrive > to client in order, > it seems this depends of switching network in between PPPoE server and client. >
If you are running a recent HEAD then you can try setting net.link.lagg.0.use_flowid to zero. Andrew _______________________________________________ [email protected] mailing list http://lists.freebsd.org/mailman/listinfo/freebsd-net To unsubscribe, send any mail to "[email protected]"