>> 19.04.06, Yuriy Tsibizov <[EMAIL PROTECTED]> написал(а): >> I run a 6.1-RC (as of Apr, 14th) and after a day nothing can be sent from em >> interface.
>> It is a filtering+accounting bridge-on-a-stick, with em interface connected >> to 3Com >> Switch 4200 100Mbit (not Gbit) port with 4 tagged vlans on it: >> Polling was not used (I'll try to work with polling enabled on em0). Polling doesn't help too >> This machine also use netgraph netflow for traffic accounting on vlan >> interfaces, >> but shutting down all netgraph nodes does not help. >> Turning vlans, bridge and em down and up does not help too. >> Traffic is received (I can see pairs of OSPF HELO messages from ISP router >> logged >> on pflog0 exactly every 10 seconds), but it looks like nothing can be sent. > try enabling pormisc mode on vlans It was enabled (it is enabled by default when you add interface to bridge, I think) It also does not explain why it work for almost a day and then stops. On switch I can see zero RX counters on this port (and non-zero TX). Yuriy. _______________________________________________ [email protected] mailing list http://lists.freebsd.org/mailman/listinfo/freebsd-stable To unsubscribe, send any mail to "[EMAIL PROTECTED]"