smartctl 6.1 2013-03-16 r3800 [FreeBSD 9.0-STABLE i386] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Hitachi Deskstar 7K160
Device Model: Hitachi HDS721680PLA380
Serial Number: PVF704Z12SS6KN
LU WWN Device Id: 5 000cca 324e6faad
Firmware Version: P21OABEA
User Capacity: 80,026,361,856 bytes [80.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 T13/1532D revision 1
Local Time is: Tue Jun 25 13:42:11 2013 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 1445) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 24) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE
UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 086 086 016 Pre-fail
Always - 131252
2 Throughput_Performance 0x0005 100 100 050 Pre-fail
Offline - 0
3 Spin_Up_Time 0x0007 129 129 024 Pre-fail
Always - 155 (Average 154)
4 Start_Stop_Count 0x0012 100 100 000 Old_age
Always - 68
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail
Always - 102
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail
Always - 0
8 Seek_Time_Performance 0x0005 100 100 020 Pre-fail
Offline - 0
9 Power_On_Hours 0x0012 095 095 000 Old_age
Always - 41836
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail
Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age
Always - 68
192 Power-Off_Retract_Count 0x0032 099 099 000 Old_age
Always - 1573
193 Load_Cycle_Count 0x0012 099 099 000 Old_age
Always - 1573
194 Temperature_Celsius 0x0002 187 187 000 Old_age
Always - 32 (Min/Max 16/44)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age
Always - 133
197 Current_Pending_Sector 0x0022 100 100 000 Old_age
Always - 1
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age
Offline - 0
199 UDMA_CRC_Error_Count 0x000a 200 253 000 Old_age
Always - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining
LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 5882 -
# 2 Short offline Completed without error 00% 5882 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Наступил конец HDD?
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE
UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 086 086 016 Pre-fail
Always - 131252
25 июня 2013 г., 12:45 пользователь Sergey Listopad
<[email protected]>написал:
> Здравствуйте коллеги.
>
> На одном маршрутизаторе появилась проблема.
>
> После "ahcich0: Timeout" файловая система на сколько я могу судить более
> не доступна. Залогиниться не получается (ни локально, ни ssh).
> Валят ошибки "/var/log device full", "create/symlink failed, no inodes
> free" (после перезагрузки проверяд df -i, inode более чем достаточно).
> shutdown по 3м кнопкам не проходит (на консоли тьма ошибок vfs_). При этом
> тело продолжает роутить, натить.
>
> Замена БП. Ситуацию не исправила, дня через 2-3 ситуация повторилась.
> Конденсаторы на материнке "визуально нормальные".
>
> smartctl завершается с ошибкой (может вызывать нужно както иначе?).
>
> Материнка Intel Desktop (если принципиально, могу уточнить модель).
>
> Пробовал dd if=/dev/ada0 of=/dev/null bs=64k завершился без ошибок.
>
> "ahcich0: Timeout" - закончился контроллер, HDD? В какую сторону копнуть?
>
> Спасибо
>
> --
> Сергей Листопад
>
--
S.Listopad