2013/6/25 Sergey Listopad <[email protected]>:
> smartctl 6.1 2013-03-16 r3800 [FreeBSD 9.0-STABLE i386] (local build)
> Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
>
> === START OF INFORMATION SECTION ===
> Model Family:     Hitachi Deskstar 7K160
> Device Model:     Hitachi HDS721680PLA380
> Serial Number:    PVF704Z12SS6KN
> LU WWN Device Id: 5 000cca 324e6faad
> Firmware Version: P21OABEA
> User Capacity:    80,026,361,856 bytes [80.0 GB]
> Sector Size:      512 bytes logical/physical
> Device is:        In smartctl database [for details use: -P show]
> ATA Version is:   ATA/ATAPI-7 T13/1532D revision 1
> Local Time is:    Tue Jun 25 13:42:11 2013 EEST
> SMART support is: Available - device has SMART capability.
> SMART support is: Enabled
>
> === START OF READ SMART DATA SECTION ===
> SMART overall-health self-assessment test result: PASSED
>
> General SMART Values:
> Offline data collection status:  (0x00) Offline data collection activity
> was never started.
> Auto Offline Data Collection: Disabled.
> Self-test execution status:      (   0) The previous self-test routine
> completed
> without error or no self-test has ever
> been run.
> Total time to complete Offline
> data collection: ( 1445) seconds.
> Offline data collection
> capabilities: (0x5b) SMART execute Offline immediate.
> Auto Offline data collection on/off support.
> Suspend Offline collection upon new
> command.
> Offline surface scan supported.
> Self-test supported.
> No Conveyance Self-test supported.
> Selective Self-test supported.
> SMART capabilities:            (0x0003) Saves SMART data before entering
> power-saving mode.
> Supports SMART auto save timer.
> Error logging capability:        (0x01) Error logging supported.
> General Purpose Logging supported.
> Short self-test routine
> recommended polling time: (   1) minutes.
> Extended self-test routine
> recommended polling time: (  24) minutes.
> SCT capabilities:       (0x003f) SCT Status supported.
> SCT Error Recovery Control supported.
> SCT Feature Control supported.
> SCT Data Table supported.
>
> SMART Attributes Data Structure revision number: 16
> Vendor Specific SMART Attributes with Thresholds:
> ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED
> WHEN_FAILED RAW_VALUE
>   1 Raw_Read_Error_Rate     0x000b   086   086   016    Pre-fail  Always
> -       131252
>   2 Throughput_Performance  0x0005   100   100   050    Pre-fail  Offline
> -       0
>   3 Spin_Up_Time            0x0007   129   129   024    Pre-fail  Always
> -       155 (Average 154)
>   4 Start_Stop_Count        0x0012   100   100   000    Old_age   Always
> -       68
>   5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail  Always
> -       102
>   7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always
> -       0
>   8 Seek_Time_Performance   0x0005   100   100   020    Pre-fail  Offline
> -       0
>   9 Power_On_Hours          0x0012   095   095   000    Old_age   Always
> -       41836
>  10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail  Always
> -       0
>  12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always
> -       68
> 192 Power-Off_Retract_Count 0x0032   099   099   000    Old_age   Always
> -       1573
> 193 Load_Cycle_Count        0x0012   099   099   000    Old_age   Always
> -       1573
> 194 Temperature_Celsius     0x0002   187   187   000    Old_age   Always
> -       32 (Min/Max 16/44)
> 196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always
> -       133
> 197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always
> -       1
> 198 Offline_Uncorrectable   0x0008   100   100   000    Old_age   Offline
> -       0
> 199 UDMA_CRC_Error_Count    0x000a   200   253   000    Old_age   Always
> -       0
>
> SMART Error Log Version: 1
> No Errors Logged
>
> SMART Self-test log structure revision number 1
> Num  Test_Description    Status                  Remaining  LifeTime(hours)
> LBA_of_first_error
> # 1  Extended offline    Completed without error       00%      5882
> -
> # 2  Short offline       Completed without error       00%      5882
> -
>
> SMART Selective self-test log data structure revision number 1
>  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
>     1        0        0  Not_testing
>     2        0        0  Not_testing
>     3        0        0  Not_testing
>     4        0        0  Not_testing
>     5        0        0  Not_testing
> Selective self-test flags (0x0):
>   After scanning selected spans, do NOT read-scan remainder of disk.
> If Selective self-test is pending on power-up, resume after 0 minute delay.
>
>
> Наступил конец HDD?

Во-первых,
>   9 Power_On_Hours          0x0012   095   095   000    Old_age   Always
> -       41836
Выбросить винт сразу, 40к часов наработки - слишком много.

Во-вторых,
> 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always
> - 133
> 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always
> - 1
Выбросить или разобрать на магнитики.

В-третьих,
>   1 Raw_Read_Error_Rate     0x000b   086   086   016    Pre-fail  Always
> -       131252
Для Hitachi это ничего не значит, там показывает хрень.

А сама ошибка больше похожа на глючащий контроллер. Но начать с винта.

Ответить