John <[EMAIL PROTECTED]> wrote: > The bugfix for Exec-Program-Wait seems to be running nicely. My new > problem that I might not have noticed before is when I'm allowing > for multiple logins. Even though radtest shows an allowance of > Port-Limit = 2, upon dialing up via multilink, I can not. ... > DEFAULT Ldap-Group == "multilink", Simultaneous-Use := 2 > Port-Limit := 2, > Idle-Timeout = 1800, > Fall-Through = Yes > DEFAULT Simultaneous-Use := 1 > Port-Limit = 1, > Idle-Timeout = 1800
Yes, you're setting 'Simultaneous-Use := 2' in the first DEFAULT, and then immediately re-setting it to 1 in the second DEFAULT. Use 'Simultaneous-Use = 1' in the second DEFAULT. Alan DeKok. - List info/subscribe/unsubscribe? See http://www.freeradius.org/list/users.html