Chris, thanks. I relooked at that after I sent the email. All is well....
Thanks for the help.. John Hengstler -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]On Behalf Of Chris Parker Sent: Monday, December 30, 2002 9:54 AM To: [EMAIL PROTECTED] Subject: RE: X-Ascend Atributes? At 09:48 AM 12/30/2002 -0800, John A. Hengstler wrote: >Woops, I did miss that subtle "X-" in the dictionary.... Fixed that. > >Now to the variable... >If I use the %{Ascend-Disconnect-Cause:-X-Ascend-Disconnect-Cause} >method to insert the variable, it inserts "X-Ascend-Disconnect-Cause" as a >string into the table, not the actual contents of the variable, but if I >change it to %{X-Ascend-Disconnect-Cause} it inserts properly. Yup, my bad. See 'doc/variables.txt' for a better explanation of how to do conditional syntax translation for your SQL inserts. You would need to actually do: %{Ascend-Disconnect-Cause:-%{X-Ascend-Disconnect-Cause}} -Chris -- \\\|||/// \ StarNet Inc. \ Chris Parker \ ~ ~ / \ WX *is* Wireless! \ Director, Engineering | @ @ | \ http://www.starnetwx.net \ (847) 963-0116 oOo---(_)---oOo--\------------------------------------------------------ \ Wholesale Internet Services - http://www.megapop.net - List info/subscribe/unsubscribe? See http://www.freeradius.org/list/users.html - List info/subscribe/unsubscribe? See http://www.freeradius.org/list/users.html