Chris,  thanks.  I relooked at that after I sent the email.

All is well....

Thanks for the help..


John Hengstler

-----Original Message-----
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED]]On Behalf Of Chris
Parker
Sent: Monday, December 30, 2002 9:54 AM
To: [EMAIL PROTECTED]
Subject: RE: X-Ascend Atributes?


At 09:48 AM 12/30/2002 -0800, John A. Hengstler wrote:
>Woops,  I did miss that subtle "X-" in the dictionary....  Fixed that.
>
>Now to the variable...
>If I use the     %{Ascend-Disconnect-Cause:-X-Ascend-Disconnect-Cause}
>method to insert the variable, it inserts "X-Ascend-Disconnect-Cause" as a
>string into the table, not the actual contents of the variable, but if I
>change it to %{X-Ascend-Disconnect-Cause} it inserts properly.

Yup, my bad.  See 'doc/variables.txt' for a better explanation of how
to do conditional syntax translation for your SQL inserts.

You would need to actually do:

%{Ascend-Disconnect-Cause:-%{X-Ascend-Disconnect-Cause}}

-Chris
--